Premium Inverter Pool Heating

Orilux OX16 & OX20 Pool Heat Pumps

High-efficiency inverter pool heating for Geelong, the Bellarine Peninsula and Surf Coast. Choose from six Orilux models covering residential pools from approximately 30m³ through to 110m³.

Get a Pool Heating Quote

Choose the Right Orilux Range

The Orilux OX16 and OX20 ranges combine high-efficiency twin-rotary DC-inverter compressor technology, spiral titanium heat exchangers and durable aluminium-alloy construction.

Both ranges offer Turbo and Smart operating modes and are designed to operate across ambient air temperatures from -15°C to 43°C.

Efficient Everyday Performance

OX16

Powerful, efficient residential pool heating.

12.5–19.5kW Turbo heating output
COP up to 16 A26 / W26 / RH80%
30–80m³ Advised pool volume
-15°C to 43°C Operating air temperature
  • Twin-rotary DC-inverter compressor
  • Turbo and Smart operating modes
  • Spiral titanium tube heat exchanger
  • Aluminium-alloy casing
  • Optional cooling capability
  • 230V single-phase power supply
Higher Efficiency & Capacity

OX20

Advanced performance for larger pools.

18.4–32.7kW Turbo heating output
COP up to 20 A26 / W26 / RH80%
45–110m³ Advised pool volume
Up to 14 COP At 50% capacity
  • Twin-rotary DC-inverter compressor
  • Turbo and Smart operating modes
  • Spiral titanium tube heat exchanger
  • Aluminium-alloy casing
  • Optional cooling capability
  • Models up to 32.7kW

OX16 & OX20 Model Range

Pool volume recommendations are indicative. Correct heat-pump sizing should also consider location, pool surface area, desired temperature, swimming season, wind exposure and pool-cover use.

OX16 Series

OX16 12.5kW

Pool: 30–50m³

Turbo: 12.5kW

Smart: 10.0kW

Maximum COP: 13.2

OX16 Series

OX16 16.5kW

Pool: 35–65m³

Turbo: 16.5kW

Smart: 13.2kW

Maximum COP: 16.0

OX16 Series

OX16 19.5kW

Pool: 45–80m³

Turbo: 19.5kW

Smart: 15.3kW

Maximum COP: 13.4

OX20 Series

OX20 18.4kW

Pool: 45–65m³

Turbo: 18.4kW

Smart: 14.1kW

Maximum COP: 20.0

OX20 Series

OX20 23.2kW

Pool: 51–75m³

Turbo: 23.2kW

Smart: 18.5kW

Maximum COP: 16.8

OX20 Series

OX20 32.7kW

Pool: 76–110m³

Turbo: 32.7kW

Smart: 25.0kW

Maximum COP: 17.0

OX16 & OX20 Technical Specifications

Compare heating capacity, efficiency, cooling performance, sound levels, electrical requirements, water flow and physical dimensions across the complete OX16 and OX20 range.

Specification OX16-12.5 OX16-16.5 OX16-19.5 OX20-18.4 OX20-23.2 OX20-32.7
Advised Pool Volume 30–50m³ 35–65m³ 45–80m³ 45–65m³ 51–75m³ 76–110m³
Operating Air Temperature -15°C to 43°C
PERFORMANCE: AIR 26°C / WATER 26°C / HUMIDITY 80%
Turbo Heating Capacity 12.5kW 16.5kW 19.5kW 18.4kW 23.2kW 32.7kW
Smart Heating Capacity 10.0kW 13.2kW 15.3kW 14.1kW 18.5kW 25.0kW
COP Range 13.2–6.4 16.0–6.6 13.4–6.3 20.0–6.9 16.8–6.6 17.0–6.5
COP at 50% Capacity 10.0 10.6 10.2 14.0 11.4 11.5
PERFORMANCE: AIR 15°C / WATER 26°C / HUMIDITY 70%
Turbo Heating Capacity 8.9kW 11.2kW 13.6kW 12.4kW 15.0kW 22.0kW
Smart Heating Capacity 7.2kW 9.0kW 10.6kW 9.3kW 12.1kW 16.8kW
COP Range 6.8–4.6 7.4–4.9 6.9–4.7 8.2–4.7 7.8–4.6 7.8–4.9
COP at 50% Capacity 6.1 6.4 6.3 7.3 6.8 6.9
COOLING: AIR 35°C / WATER 28°C / HUMIDITY 80%
Cooling Capacity (Optional) 5.2kW 6.4kW 7.2kW 6.8kW 8.3kW 13.9kW
SOUND PERFORMANCE
Sound Pressure at 1m 42.5–53.0 dB(A) 43.2–55.0 43.7–57.0 42.9–52.0 42.1–53.0 43.1–54.9
Sound at 50% Capacity / 1m 46.8 dB(A) 47.5 49.6 45.7 46.3 47.1
Sound Pressure at 10m 22.5–33.6 dB(A) 23.2–35.8 23.7–37.0 21.5–32.0 22.1–33.6 23.1–34.9
COMPONENTS
Compressor Twin-Rotary DC-Inverter
Heat Exchanger Spiral Titanium Tube in PVC
Casing Aluminium-Alloy Casing
ELECTRICAL & HYDRAULIC
Power Supply 230V / 1Ph / 50Hz
Water Connection 50mm
Rated Input Power at 15°C 0.21–1.93kW 0.24–2.29kW 0.31–2.39kW 0.23–2.64kW 0.31–3.25kW 0.43–4.49kW
Rated Input Current at 15°C 0.91–8.4A 1.04–10A 1.35–12.6A 1–11.48A 1.35–14.77A 1.87–19.52A
Advised Water Flow 4–6m³/h 6.5–8.5m³/h 8–10m³/h 4–6m³/h 6.5–8.5m³/h 10–12m³/h
Maximum Input Current 10A 16A 18A 14A 17A 27A
Estimated Circuit Breaker 12A 20A 20A 16A 20A 30A
DIMENSIONS & WEIGHT
Dimensions L × W × H 894 × 290 × 648mm 954 × 359 × 648mm 954 × 359 × 747mm 929 × 432 × 650mm 965 × 432 × 750mm 1074 × 539 × 647mm
Estimated Net Weight 61kg 74kg 78kg 68kg 96kg 118kg

Published performance figures are based on the stated test conditions. Actual heating capacity and efficiency vary with ambient temperature, water temperature, humidity, installation and operating conditions. Specifications are subject to modification without notice.

Engineered for Efficient Pool Heating

Both Orilux ranges use variable-capacity inverter technology to adjust heating output according to pool demand.

Rather than relying on fixed-speed operation, the compressor can modulate its output as heating requirements change.

  • Twin-rotary DC-inverter compressor
  • Spiral titanium heat exchanger
  • Turbo heating mode
  • Smart inverter operation
  • Heating and optional cooling
  • Quiet variable-speed operation
  • -15°C to 43°C ambient operating range

Orilux Pool Heat Pumps for Geelong

Geelong Pool Heating supplies and installs Orilux pool heat pumps throughout Geelong, the Bellarine Peninsula and Surf Coast.

Correct heat-pump sizing is particularly important in Victoria. Pool surface area, local climate, wind exposure, target temperature, pool-cover use and the length of your swimming season can all influence the required heating capacity.

Which Orilux Heat Pump Do You Need?

Tell us your pool dimensions, suburb, target water temperature and swimming season and we'll help determine the right OX16 or OX20 model for your pool.

Get My Heat Pump Recommendation
Pool Heat Pump Calculator

Find the Right Orilux Heat Pump

Enter your pool size and operating conditions to find a recommended Orilux pool heat pump. Sizing is adjusted for Geelong, Melbourne and cooler Victorian conditions to help avoid undersizing.

Most residential pools are around 1.3m–1.6m average depth.
This calculator is a sizing guide only. Final heat pump sizing should consider wind exposure, plumbing, pool cover use, target temperature, installation location and customer expectations.

Your Recommended Heat Pump Size

Based on your pool volume and selected operating conditions.

22kW
48,000L pool Cool climate sizing Performance sized
Orilux heat pumps use R290 refrigerant. COP ratings shown are maximum laboratory performance figures and may vary depending on air temperature, water temperature, humidity, installation conditions and operating mode.